China OEM Motor Coupling Magnetic Coupling Pump Motor Shaft Coupling motor coupling

Product Description

Hot sale: low noise,no leakage, no additional cost for motor coupling magnetic coupling pump motor shaft coupling

Please send us following information.
1. Motor output power(KW)
2. Motor speed(RPM)
3.Torque of the mangetic coupling
4. Working pressure of the housing(isolation sleeve)
5.Working temperature of magnetic coupling
6. Technical drawing of the output part connector (usually motor)
7. Technical drawing of the input part connector (usually pump)

Introduction of motor coupling magnetic coupling pump motor shaft coupling

Magnetic shaft coupling is a new kind of coupling, which connects motor and machine by permanent magnetic force. 

They are consisted of external rotor, internal rotor and isolating covers.

They work in the sealed magnetic drive pumps, which transporting volatile, flammable, explosive and toxic solutions with no leakage. 

These magnetic shaft couplings can be used to connect gear pumps , screw pumps, centrifugal pumps, etc. with all types of electric motor or gear box. 

Magnetic shaft coupling are widely used in various industries and fields, such as chemical, papermaking, foodstuff, pharmacy, and so on. 

Advantages of motor coupling magnetic coupling pump motor shaft coupling

» Elimination of fluid leakage from the pump shaft.

» Vibrations are not transmitted to the pump.

» No maintenance required for magnetic couplings.

» Using magnetic couplings allows use of standard pumps without expensive mechanical seals.

» No additional cost for purchasing mechanical seal spare parts and maintenance.

 

Technical drawing of motor coupling magnetic coupling pump motor shaft coupling

Specification of motor coupling magnetic coupling pump motor shaft coupling

Item Internal Rotor(mm) External Rotor(mm) Isolating Covering(mm)
A B C D E F G Shaft Pin H I J L N M P Q R S T U
GME03-3LM00 Φ35 Φ10 26 18 M6X12 Φ42 Φ60 Φ50 46 6-M4 Φ40 Φ50 4-Φ5.4 Φ38 Φ60 6 6
GME03-5MM00 Φ42 Φ12 27 4 18 13.8 M6X16 Φ49 Φ72 Φ60 46 4-Φ6.7 Φ52 Φ60 4-Φ6.7 Φ44 Φ74 8 8
GME03-16LM00 Φ56 Φ12 45 4 25 13.8 M6X16 Φ63 Φ89 Φ80 75 6-M5 Φ70 Φ75 4-Φ6.7 Φ58 Φ89 8 8
GME03-16LM01 Φ56 Φ12 45 4 25 13.8 M6X16 Φ63 Φ89 Φ80 75 4-M5 Φ70 Φ75 4-Φ6.7 Φ58 Φ89 6 10
GME03-16MM00 Φ56 Φ12 45 4 25 13.8 M6X16 Φ63 Φ89 Φ80 75 6-M5 Φ70 Φ75 4-Φ6.7 Φ58 Φ89 8 8
GME03-22LM00 Φ88 Φ20 29 6 25 22.8 M8X20 Φ97 Φ122 Φ110 70 8-M6 Φ98 Φ108 6-Φ6.7 Φ91 Φ122 8 8
GME03-30LM00 Φ88 Φ20 48 6 30 22.8 M8X20 Φ97 Φ122 Φ110 81 8-M6 Φ98 Φ108 6-Φ6.7 Φ91 Φ122 8 8
GME03-40LM00 Φ101 Φ25 49 8 28 28.3 M10X20 Φ109 Φ140 Φ124 83 8-M8 Φ110 Φ126 8-Φ6.7 Φ103 Φ140 12 6
GME03-50LM00 Φ107 Φ20 70 6 30 22.8 M6X16 Φ113.4 Φ145 Φ135 80 4-M6 Φ126 Φ133 12-Φ8.7 Φ109 Φ153 12 15
GME03-65LM00 Φ101 Φ25 77 8 45 28.3 M10X20 Φ109 Φ140 Φ124 111 8-M8 Φ110 Φ126 8-Φ6.7 Φ103 Φ140 12 6
GME03-80LM00 Φ106 Φ32 65 10 21 36.5 M6X25 Φ115 Φ145 Φ135 82 4-M6 Φ127 Φ135 6-Φ8.7 Φ110 Φ153 13 18
GME03-80LM00 Φ141 Φ92 Φ40 65 12 45 43.3 M12X25 Φ152 Φ180 Φ168 100 8-M8 Φ154 Φ164 8-Φ6.7 Φ145 Φ180 12 8
GME03-100LM00 Φ131 Φ82 Φ32 80 10 24.5 35.3 M8X35 Φ139 Φ170 Φ160 100 4-M6 Φ152 Φ158 8-Φ8.7 Φ133 Φ178 14 21
GME03-110LH00 Φ141 Φ92 Φ40 85 10 50 43.3 M12X25 Φ152 Φ184 Φ168 115 12-M8 Φ156 Φ164 12-Φ6.7 Φ145 Φ180 12 3
GME03-110LM00 Φ141 Φ92 Φ35 80 10 55 38.3 M12X25 Φ152 Φ180 Φ168 115 12-M8 Φ154 Φ164 12-Φ6.7 Φ145 Φ180 12 3
GME03-140LM00 Φ141 Φ92 Φ40 110 12 80 43.3 M12X25 Φ152 Φ190 Φ170 145 12-M10 Φ154 Φ164 12-Φ6.7 Φ145 Φ180 12 3
GME03-180LM00 Φ141 Φ92 Φ40 140 12 95 43.3 M12X25 Φ152 Φ190 Φ170 175 12-M10 Φ154 Φ164 12-Φ6.7 Φ145 Φ180 12 3
GME03-220LM00 Φ141 Φ92 Φ48 160 14 110 51.8 M12X25 Φ152 Φ190 Φ170 195 12-M10 Φ154 Φ164 12-Φ6.7 Φ145 Φ180 12 3
GME03-300LM00 Φ162 Φ65 100 18 60 69.4   Φ170 Φ198 Φ188 123 12-M6 Φ180 Φ192 12-Φ11 Φ163.5 Φ218 16 10
GME03-400LH00 Φ195 Φ70 127 20 107 79.9 M12X25 Φ203 Φ234 Φ222 152 6-M6 Φ212 Φ164 12-Φ11 Φ198 Φ278 16 22

Application of motor coupling magnetic coupling pump motor shaft coupling

The ability to hermetically separate 2 areas whilst continuing to transmit mechanical power from one to the other makes these couplings ideal for applications where prevention of cross contamination is essential. For instance: hydraulic sectors, dosing systems, compressors, sterilizers, industrial ovens, biotechnology, subsea equipment, pharmaceutical industry, chemical industry, food industry, generators and mixers.

 

 

 

Operation principles of motor coupling magnetic coupling pump motor shaft coupling

The magnetic coupling works by using the power generated by permanent magnets. No external power supply is needed. These are permanent magnets not electro magnets.

 

Packing Method of motor coupling magnetic coupling pump motor shaft coupling

Double strength corrugated Carton and Wood case Sea Packing.

 

 

/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

motor coupling

Understanding the Torque and Misalignment Capabilities of Motor Couplings

Motor couplings play a crucial role in transmitting torque from the motor to the driven equipment while accommodating certain degrees of misalignment between the shafts. Here’s a detailed explanation of their torque and misalignment capabilities:

Torque Transmission:

Torque transmission is one of the primary functions of a motor coupling. It refers to the ability of the coupling to transfer rotational force (torque) from the motor shaft to the driven equipment shaft. The torque capacity of a coupling depends on various factors, including:

  • Coupling Type: Different coupling types have varying torque capacities. For instance, gear couplings have high torque capacity, making them suitable for heavy-duty applications.
  • Material and Design: The material and design of the coupling elements play a role in determining its torque capacity. Couplings made from high-strength materials can handle higher torque loads.
  • Size: The size of the coupling affects its torque capacity. Larger couplings generally have higher torque ratings.
  • Operating Conditions: Environmental factors, temperature, and speed also influence the torque capacity of the coupling.

Misalignment Compensation:

Motor couplings are designed to accommodate a certain degree of misalignment between the motor and driven equipment shafts. Misalignment can occur due to factors such as manufacturing tolerances, thermal expansion, and operational conditions. The misalignment capability of a coupling depends on its type and design:

  • Flexible Couplings: Flexible couplings, such as jaw couplings or elastomeric couplings, can handle both angular and parallel misalignment. They provide some flexibility to dampen vibrations and compensate for minor misalignment.
  • Universal Joints: Universal joints can handle angular misalignment and are commonly used in applications requiring a high range of motion, such as vehicle drivelines.
  • Disc Couplings: Disc couplings can handle angular misalignment and provide high torsional stiffness for precision applications.
  • Bellows Couplings: Bellows couplings are suitable for applications requiring high levels of parallel misalignment compensation, such as in optical equipment.

It is essential to consider the torque and misalignment requirements of the specific application when selecting a motor coupling. Properly matching the coupling’s capabilities to the system’s needs ensures efficient torque transmission and helps prevent premature wear or failure due to misalignment issues.

“`motor coupling

Comparing Motor Couplings with Direct Drives and Other Power Transmission Methods

Motor couplings, direct drives, and other power transmission methods each have their advantages and disadvantages, making them suitable for different applications. Let’s compare these methods in terms of various factors:

1. Efficiency:

Motor couplings generally offer high efficiency in power transmission since they provide a direct mechanical connection between the motor and driven equipment. In contrast, direct drives can also be efficient as they eliminate the need for intermediate components.

2. Misalignment Compensation:

Motor couplings are designed to accommodate misalignments between the motor and driven equipment shafts, making them suitable for applications where misalignment is expected. Direct drives, on the other hand, require precise alignment between the motor and driven equipment.

3. Maintenance:

Motor couplings often have minimal maintenance requirements since they do not have intricate components. Direct drives can be maintenance-free as well since they eliminate the need for belts, chains, or gears.

4. Backlash:

Motor couplings typically have low or zero backlash, ensuring precise torque transmission. Direct drives also offer low or no backlash since there are no intermediate components to introduce play.

5. Cost:

Motor couplings are generally more cost-effective compared to direct drives, which may involve higher initial investment in specialized components. However, the overall cost may vary depending on the application and system requirements.

6. Space and Size:

Motor couplings are compact and can fit in tight spaces, making them suitable for applications with limited room. Direct drives may require more space, depending on their design and motor size.

7. Shock Absorption:

Motor couplings, especially those with elastomeric elements, can absorb shocks and vibrations, protecting the motor and driven equipment. Direct drives may not have the same level of shock absorption.

8. Torque Transmission:

Both motor couplings and direct drives are efficient in torque transmission. However, some direct drives may offer higher torque capacity for heavy-duty applications.

9. Installation Complexity:

Motor couplings are generally easier to install compared to direct drives, which may involve more intricate assembly and alignment procedures.

10. Application:

Motor couplings are versatile and can be used in various industrial setups, especially when misalignment compensation is required. Direct drives are commonly found in applications where high precision and direct mechanical connection are crucial.

Ultimately, the choice between motor couplings, direct drives, and other power transmission methods depends on the specific needs and constraints of the application. Each method offers distinct advantages, and selecting the most suitable option requires careful consideration of the application’s requirements, space limitations, budget, and maintenance preferences.

“`motor coupling

How Does a Flexible Motor Coupling Differ from a Rigid Motor Coupling?

Flexible motor couplings and rigid motor couplings are two distinct types of couplings used to connect motors to driven equipment. They differ significantly in their design, function, and applications:

Flexible Motor Coupling:

A flexible motor coupling is designed to accommodate misalignment between the motor shaft and the driven equipment shaft. It uses flexible elements, such as elastomeric materials, to provide some degree of flexibility and damping. The key differences are:

  • Misalignment Compensation: Flexible couplings can handle both angular and parallel misalignment between the motor and driven equipment shafts. This flexibility reduces stress on bearings and allows for a smoother transmission of torque.
  • Shock Absorption: The elastomeric elements in flexible couplings can absorb and dampen vibrations and shock loads, protecting the motor and driven equipment from damage.
  • Applications: Flexible couplings are commonly used in applications where misalignment is expected, such as pumps, compressors, conveyors, and machine tools.

Rigid Motor Coupling:

A rigid motor coupling provides a solid and inflexible connection between the motor shaft and the driven equipment shaft. It does not allow any misalignment and offers a direct torque transmission path. The key differences are:

  • No Misalignment Compensation: Rigid couplings do not accommodate misalignment between the motor and driven equipment shafts. Proper alignment is critical for their efficient operation.
  • Stiffness: Rigid couplings offer high torsional stiffness, maintaining precise alignment between the shafts and enabling accurate torque transmission.
  • Applications: Rigid couplings are used in applications where precise alignment is required, such as high-precision machine tools, robotics, and applications with low or negligible misalignment.

The choice between a flexible motor coupling and a rigid motor coupling depends on the specific requirements of the application. Flexible couplings are preferred when misalignment is expected, while rigid couplings are suitable for applications where precise alignment and direct torque transmission are essential for the system’s performance.

“`
China OEM Motor Coupling Magnetic Coupling Pump Motor Shaft Coupling   motor couplingChina OEM Motor Coupling Magnetic Coupling Pump Motor Shaft Coupling   motor coupling